Tl-audio 5050 User Manual

Browse online or download User Manual for Audio Tl-audio 5050. TL Audio 5050 User Manual [fr] [de] [it] [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
user manual
TL A
udio
®
Ivory 2 Series
5050
MONO VALVE PREAMP
& COMPRESSOR
TL Audio Ltd, Letchworth, Herts, SG6 1AN, UK
email: [email protected] web: http://www.tlaudio.co.uk
Page view 0
1 2 3 4 5 6 ... 21 22

Summary of Contents

Page 1 - Ivory 2 Series

user manualTL Audio®Ivory 2 Series5050MONO VALVE PREAMP& COMPRESSORTL Audio Ltd, Letchworth, Herts, SG6 1AN, UKemail: [email protected] web: ht

Page 2 - CONTENTS

FUSE T1AL 250V230V~25VA 115V~25VACAUTIONRISK OF ELECTRIC SHOCKDO NOT OPENATTENTIONRISQUE DE CHOC ELECTRONIQUENE PAS OUVRIRManufactured by TL Aud

Page 3

4.1 Front Panel. The front panel controls are identified in Fig.2. 4.2 Input Selection. The input source is selected by the push button ad

Page 4 - 1. INTRODUCTION

input gain can then be gradually increased until the output level LED bargraph illuminates to about 0dB on normal signal level. The master output le

Page 5

controlled automatically, allowing the engineer to get on with more productive jobs! Many instruments and voices have a very wide dynamic range tha

Page 6 - 2. PRECAUTIONS

To operate the 5050 successfully, an understanding of each control will help to obtain the best results. If you are unfamiliar with the effect of c

Page 7 - 3. INSTALLATION

drops back below the threshold. The 5050 Attack and Release controls each allow a choice of ‘Fast’ and ‘Slow’ modes. The Attack times are 0.5mS (Fas

Page 8

adjusted, use the Output Level control to set the overall output level of the 5050. 4.17 Compressor On. This switch enables or disables the comp

Page 9 - 4. OPERATION

44.1kHz or to 48kHz, and the card can be clocked to an external digital source via the BNC wordclock input. When clocking the DO-2 to an external so

Page 10 - FIG 3: REAR PANEL

returns, then connecting the 5050 into the relevant console channel insert point. The off-tape signal will then be fed into the 5050’s line input vi

Page 11

place. Aim to get around a maximum 3-4dB of gain reduction occurring as a starting point, by lowering the Threshold further if necessary. You should

Page 12

CONTENTS 1 INTRODUCTION 2 PRECAUTIONS 3 INSTALLATION 3.1 A.C. Mains Supply 3.2 Audio Operating Level 3.3 Microphone Input 3.4 Line Input 3.5

Page 13

Phantom Power: +48V at 10mA maximum. High Pass Filter: -3dB at 90Hz, 12dB per octave. Balanced Line Input: Electronically balanc

Page 14

10Hz to 40KHz, +0, -1dB. Noise: -80dBu, 22Hz to 22KHz, line input selected at 0dBu input and output gain. Dynamic Range: 100dB (Li

Page 15

7. SERVICE Should the 5050 require service, it must be taken or posted to an authorised dealer. Please retain the original packing for possi

Page 17 - 5. GETTING STARTED

7 SERVICE 1. INTRODUCTION Congratulations on purchasing the Ivory 5050 Mono Preamp & Compressor by TL Audio! The Ivory 2 Series consists of

Page 18

The output is via a balanced jack socket at a nominal level of +4dBu. Metering of the output is by an 8 segment LED bargraph. Please read this manu

Page 19 - 6. SPECIFICATIONS

2. PRECAUTIONS The T L Audio 5050 requires very little installation, but like all electrical equipment, care must be taken to ensure reliabl

Page 20

3. INSTALLATION 3.1 AC Mains Supply. The unit is fitted with an internationally approved 3 pin IEC connector. A mating socket with power cord i

Page 21

- Pin 3 = Signal Non-Phase (“-” or “cold”). Unbalanced inputs: - Pin 1 = Ground (screen) - Pin 2 = Signal Phase (“+” or “hot”). -

Page 22 - 7. SERVICE

The instrument input has a 1MΩ impedance and is suitable for direct connection of instruments including guitars, bass guitars and keyboards. Good qu

Comments to this Manuals